- Can be installed in safety zones 1 and
2 as established by the IEC 364- 7 where risk of electrical
contact is high.
- 220÷240/12V~ transformer, in
accordance with IEC 742 class II, IP22 protected with safety
thermostat.
- The very low power voltage of the
Silente 12 Volt, (SELV - Safety Extra Low Voltage), with the use
of a special transformer supplied with the fan, permits
installation even in proximity of the bath tub as the eventual
direct contact with the fan does not pose any threat of
electrical danger.
Download the data sheet of this Product
|
|
IEC 364-7 standard, on Part 7 contains a section dedicated to “Locations
containing a bath tub or shower basin” where, says the text “ the
risk of electric shock is increased by a reduction in body
resistance and contact of the body with earth potential”. In order
to avoid this high risk of electric shock the standard classifies in
the room different zones and for each zone prescribes different
installation limits of electrical components. The standard describes
the different zones as follows:
- Zone 0: is the interior of the bath
tub or shower basin.
- Zone 1: is limited by the vertical
plane circumscribing the bath tub or shower basin, by the floor
and the horizontal plane 2.25 m. above the floor.
- Zone 2: is limited by the vertical
plane external to Zone 1 and the parallel vertical plane 0,60 m.
external to Zone 1, by floor and the horizontal plane 2,25 m.
above the floor.
- Zone 3: is limited by the vertical
plane external to Zone 2 and the parallel vertical plane 2,40 m.
external to Zone 2, by floor and the horizontal plane 2,25 m.
above the floor.
For each zone the standard makes a list of the prescriptions for
the electrical equipment that may be or may not be installed as
follows:
- In zone 0, only electrical appliances
specially intended for use in a bath tub are permitted.
- In zone 1, only water heaters or SELV
type appliances (Safety Extra Low Voltage) may be installed.
- In zone 2 only water heaters, and
Class II luminaires or SELV type appliances may be installed.
- In zone 3 there are no limits for
installation of electrical equipment, but anyway the eventual “
Switchgear and Controlgear” must be as follows: supplied
individually by an isolating transformer, supplied by SELV,
protected by a residual current protective device with a
residual operating current not exceeding 0,03 A.
Hence, in zone 1 or 2 or 3 only a 12 V SELV fan should be
installed. |